Ten protocols, in one program or separately

All the programs only read: they do not change device values or settings and do not send control commands.

Downloads — coming soon Write to us

PLC 48213 kWh Modbus DLMS SNMP 400011500 1-0:1.8.0.25548213 kWh 1-0:32.7.0.255229 V ifOperStatus.1up(1)

MasterGateway or Master Protocols

MasterGatewayMaster Protocols
ProtocolsAll ten, also at the same time (OPC DA on Windows only)One per program
Terminalmasterkontact-cli—
LicenseBy protocols and number of variablesPer program
Without a license10-minute demo mode10-minute free trial

MasterGateway

Windows and Linux · window and terminal

All ten protocols in a single window, with a coloured dot showing the state of each connection.

  • License by protocols and number of variables
  • Hardware page: network, serial ports and computer
  • License events in the Event Viewer or in syslog

masterkontact-cli: the same reads from the terminal, also on Linux servers without a desktop.

Master Protocols

One program for each protocol, with its own license. The functions are the same as in MasterGateway.

BACnet

Master Protocols — compatible with BACnet

Reads objects and properties of building controllers: HVAC, lighting…

  • BACnet/IP and MS/TP (RS-485)
  • Never uses WriteProperty
  • Windows and Linux

SNMP

Master Protocols — compatible with SNMP

Reads OIDs, tables and traps from switches, routers, UPSs and servers.

  • SNMP v1, v2c and v3, encryption included
  • Never sends Set
  • Windows and Linux

Modbus

Master Protocols — compatible with Modbus

Reads registers and coils of PLCs, meters and drives.

  • Modbus TCP, RTU and ASCII, over the network or a serial port
  • Read functions only
  • Windows and Linux

OPC UA

Master Protocols — compatible with OPC UA

Reads nodes and values from the OPC UA servers of PLCs, SCADA systems and gateways.

  • Anonymous, user or certificate access, also encrypted
  • Never uses Write or Call
  • Windows and Linux

OPC DA

Master Protocols — compatible with OPC DA

Reads items with value, quality and timestamp from OPC DA servers.

  • OPC DA 2.0 and 3.0, on the same PC or another one (DCOM)
  • Never writes to the server
  • Windows only, with the 64-bit OPC Core Components

IEC 60870-5-104

Master Protocols — compatible with IEC 60870-5-104

Reads measurements, signals and counters from RTUs and substations.

  • IEC 60870-5-104 over TCP
  • Never sends control commands
  • Windows and Linux

DLMS/COSEM

Master Protocols — compatible with DLMS/COSEM

Reads energy, registers and load profiles from meters.

  • Over the network, a serial port or an optical probe
  • Never uses SET
  • Windows and Linux

PROFINET DCP

Master Protocols — compatible with PROFINET DCP

Finds the PROFINET devices on the network, with their name and IP.

  • Never changes names or IP addresses
  • On Windows with Npcap, on Linux as root
  • Windows and Linux

PROFINET IO

Master Protocols — compatible with PROFINET IO

Reads nameplate data, modules, diagnostics and ports of PROFINET IO devices.

  • By IP address, no Npcap needed
  • Never uses Connect or Write
  • Windows and Linux

PROFINET RT

Master Protocols — compatible with PROFINET RT

Listens to the cyclic traffic and alarms between the controller and the devices.

  • From a mirror port, a TAP or a capture file
  • Never transmits
  • On Windows with Npcap, on Linux as root

MasterGateway Diagnostica

Windows and Linux · free, no license

For when a connection does not work: it shows the state of MasterGateway's connections, tests the connection to a device and shows the network and serial ports. It does not read plant data.

In all the programs

Saved connection profiles, a watch list with value, status and time, automatic reconnection and an interface in five languages. With a license, export to CSV.

System requirements

  • Windows 10 or 11, 64-bit: all the programs. No need to install .NET.
  • Linux x86-64 with a desktop: all, except OPC DA.
  • Linux without a desktop: masterkontact-cli and masterkontact-diag.
  • PROFINET DCP and RT: on Windows they need Npcap, which we do not include; download it from npcap.com. Npcap belongs to Nmap Software LLC and has its own license: the free edition can be installed on at most five computers (virtual machines included); for more, a commercial license is needed. On Linux, start them as root.

Try it for 10 minutes, free

No license and no registration needed. To save, export or copy data you need a license.